So in DS I exported a QT Ref from the original 1080p 23.98 sequence and imported that back in as 720p 59.94 and had DS rescale. That worked fine. Still a very strange issue I need to look into more.
Thanks,
KEN
--- In Avid-L2@yahoogroups.com, "ksirul" <kenavid2@...> wrote:
>
> Lowpass. Like I mentioned, it all looks good at 1080i or p, whichever we send to the edit room. It's only 720p that's problematic.
>
> --- In Avid-L2@yahoogroups.com, Bogdan Grigoresco <bogdan_grigorescu@> wrote:
> >
> > Are your scopes set for lowpass?
> >
> > cheers,
> > Bogdan Grigoresco
> > www.finale.tv
> >
> > --- On Sat, 5/14/11, ksirul <kenavid2@> wrote:
> >
> > From: ksirul <kenavid2@>
> > Subject: [Avid-L2] Re: 1080 to 720 levels Q
> > To: Avid-L2@yahoogroups.com
> > Date: Saturday, May 14, 2011, 3:47 AM
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > Â
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > We looked at a Leader 5700 scope in 2 separate edit rooms (DS and Symphony) looking at the converted signal. Yes, the scope is changing to match the rate. I tried both NTSC BlackBurst and 720p TriLevel Sync. It's very strange. The 1080p 23.98 output is fine. Using the deck to convert to 1080i 59.94 is fine. Using the deck OR the Teranex to downconvert to 720p 59.94 has the problem. It is certainly (not likely though) that both the SR Format converter and the Teranex are not working correctly but that seems to random (but not ruling it out yet). I've spoken to Sony and they are looking into it. It was too late by the time I left a message with Teranex.
> >
> >
> >
> > --- In Avid-L2@yahoogroups.com, "oliverpetersvidy" <oliverpeters@> wrote:
> >
> > >
> >
> > > > ksirul wrote:
> >
> > > > I have a film on HDCam SR 422 1080p 23.98 sf. I am trying to capture
> >
> > > > at 720p 59.94. What is happening in 720p is that whites seem to be
> >
> > > > showing at 110IRE and blacks at -10 on the scope.
> >
> > > >
> >
> > >
> >
> > > Where are you making this evaluation? On an external scope connected directly to the machine? Is the scope resetting to match the signal? 1080i/PsF calibration or 720p calibration according to the signal changes.
> >
> > >
> >
> > > - Oliver
> >
> > >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > [Non-text portions of this message have been removed]
> >
>
If you want to donate to Red Cross quake relief, you can do so through your cell phone. Text redcross to 90999 to make a $10 donation. It will be on your next cell bill.
No comments: