In order to perform a pulldown with consistent cadence, the deck needs interlocked trilevel 23.98 and bilevel 29.97 sync. Also, in the PD section of the VTR setup menu, item A05-PDREF must be set to 'lock2'
In the Avid, you need to start the capture at a '00' or '05' timecode frame count.
cheers,
BG
www.finale.tv
--- On Thu, 12/13/12, ksirul <kenavid2@glueedit.com> wrote:
From: ksirul <kenavid2@glueedit.com>
Subject: [Avid-L2] Re: 23.98 NTSC offline Q
To: Avid-L2@yahoogroups.com
Date: Thursday, December 13, 2012, 10:54 AM
That's what we are doing now. I haven't loaded into a 23.98 SD project in years. I had thought that even though PD was being added at the deck, it would get removed during capture into a 23.98 project.
KEN
--- In Avid-L2@yahoogroups.com, electropura212 <electropura212@...> wrote:
>
> The SD output of the deck has pulldown added. Why not capture DNX 36 and
> keep it HD? You can mix that with your SD 3:1 footage no problem. Your
> avid will down convert on the fly. The file size will be manageable.
>
> On Thursday, December 13, 2012, ksirul wrote:
>
> > **
> >
> >
> > Client has an HDCam SR 422 tape that is at 1080p 23.98sf. We need to
> > capture it at 3:1 into a 23.98 SD project for offline. What is the best way
> > to do this? We originally took the SD output out of the SRW5800 into MC and
> > captured like that. The clips in their project are counting 30 frame tc and
> > also have interlacing artifacts. We captured starting at even frame
> > numbers. I'm sure I'm doing something wrong here. Is there a way to do this
> > without using a Teranex to downconvert?
> >
> > KEN
> >
> >
> >
>
>
> [Non-text portions of this message have been removed]
>
[Non-text portions of this message have been removed]